Radiator thermostatic controller – also known as: RADIATOR VALVES-S3030. In recent years, temperature control valves have been widely used in new residential buildings in my country, and temperature control valves are installed on heating radiators in residential and public buildings.

radiator

The temperature control valve can set the room temperature according to the different requirements of users. Its temperature sensing part continuously senses the room temperature and automatically adjusts the supply of heat at any time according to the current heat demand to prevent the room temperature from overheating and achieve the highest comfort for the user.

The temperature control in the user’s room is realized by the radiator thermostatic control valve. The radiator thermostatic control valve is composed of a thermostatic controller, a flow regulating valve and a pair of connectors. The core component of the thermostatic controller is the sensor unit, that is, the temperature bulb. The temperature bulb can sense the change of ambient temperature to produce volume change, drive the valve core of the regulating valve to produce displacement, and then adjust the water volume of the radiator to change the heat dissipation of the radiator. The set temperature of the thermostatic valve can be adjusted manually, and the thermostatic valve will automatically control and adjust the water volume of the radiator according to the set requirements, so as to achieve the purpose of controlling the indoor temperature. The temperature control valve is generally installed in front of the radiator to automatically adjust the flow to achieve the room temperature required by the residents. The temperature control valve is divided into two-way temperature control valve and three-way temperature control valve. The three-way temperature control valve is mainly used in a single-pipe system with a spanning pipe. Its diversion coefficient can be changed in the range of 0 to 100%, and the flow adjustment has a large room, but the price is relatively expensive and the structure is more complicated. Some two-way temperature control valves are used in two-pipe systems, and some are used in single-pipe systems. The two-way thermostatic valve used in the double-pipe system has a larger resistance; the resistance used in the single-pipe system is smaller. The temperature sensor package and the valve body of the temperature control valve are generally assembled into a whole, and the temperature sensor package itself is the on-site indoor temperature sensor. If necessary, a remote temperature sensor can be used; the remote temperature sensor is placed in the room that requires temperature control, and the valve body is placed in a certain part of the heating system.


Post time: Jan-25-2022